DC
Power Products
• Battery
Chargers
• StartNow
AC Power Products
• Isolation
Transformer
• A/B
Selector
Onboard Communications System
• C-Phone
Shore Power Cables
• Smart
Y
Please
have the following information available when contacting Charles
Industries for assistance -
• Serial number of the product
• Approximate purchase date of the product
• Note any indicators or discrepancies
Be prepared to take notes for further troubleshooting or return
information.
Any
electrical measurements should be made by a qualified technician.
DC Power Products - Battery
Chargers
What are the proper AC and DC fuse or Circuit Breaker sizes for my
Battery Charger?
The AC fuse or
circuit breaker is equivalent to the AC AMPS rating on the label
located on the right side of the unit.
The
DC fuse is equivalent to approx. 120% the rated output of the
Battery Charger, but no larger than 150% the rating of the wire.
Does
my Battery Charger ever completely shut off?
No, the battery charger will remain on is a lowered rate of charge,
to act as a power supply and maintain the batteries.
Why
do my
batteries appear to be boiling?
The electronic series battery charger we produce is a multi-stage
charger.
You
may be witnessing the first stage, the "bulk/high" rate of
charge, which has a timed function of 4 hrs. After which, the unit
will then cycle to the "float/trickle" rate of charge.
Why
do I seem to add a lot of water to my flooded batteries?
Flooded batteries will always evaporate fluids while being
discharged and recharged, higher usage will require higher
maintenance.
If
the charger is being cycled on and off, not being allowed to operate
for the full 4 hrs of "bulk/high" rate, the output voltage
may effectively remain in the "bulk/high" rate. This will
cause additional evaporation/out-gassing of the battery's fluids.
It
is important to allow the battery charger time to cycle through the
charging stages, ending in the “float/maintenance” stage.
Is
there an adjustment that can be help cut back on fluid evaporation?
An easy way to "taper" back the amount of energy being
supplied to the battery(s) would be to switch the "battery type
selector" switch to GEL or even AGM. This will lower the peak
voltage allowed to the battery(s) from the charger.
Can
I use a Lead Acid/Flooded Cell Battery Charger on a Gel Battery?
Although a Flooded type battery charger could charge the battery, it
is not recommended for typical charging/maintenance.
Can
I use a GEL Battery
Charger on a Lead Acid Battery?
Our GEL charger can adequately maintain a Lead Acid battery, but it
may not allow the Lead Acid battery to reach peak potential.
What
size charger do I need?
For standard and deep cycle batteries, we recommend sizing the
charger to (50% of the total AHrs of the house/accessory battery
bank) / 8 hours of recharging/recovery time.
The
'hours of recharging/recovery' may be changed to accommodate faster
recharging time, but we recommend not exceeding an average of 25
amps per battery.
For
starting batteries, we recommend sizing the charger to (25% of the
total AHrs of the house/accessory battery bank) / 8 hours of
recharging/recovery time.
Why
is the needle on the meter always showing max amps?
It simply may be overloaded. Try to lighten the load by temporarily
disconnecting some of the batteries or turn some DC loads off.
The
battery charger will respond like a power-supply, thus as DC loads
appear it will react by supplying energy until it reaches its ampere
limit.
A
battery may be damaged. The charger can't distinguish between loads
and the batteries, good or bad. Touch your batteries to see if
any are hot. If so, turn off the battery charger and see if the
battery voltage quickly drops, indicating a damaged cell(s).
Why
is the needle on the meter always showing 0 amps?
It is an indication of the batteries being charged or the charger
has no load applied.
To
test the charger, try turning on DC cabin lights. On a 12-volt
system, 100 watts is about 7.5 amps (+/-2 amps) On a 24 volt system,
200 watts is about 7.5 amps.
Can
you please tell me the difference between 2000 and 5000 model
charger lines?
The primary differences between the 2000 and 5000 models are:
1.
The
5000-Series is UL certified and the 2000-Series is not UL certified.
2.
The 5000-Series has better EMI filtering
(Electromagnetic Interference) providing additional
protection from
the radio frequency spectrum of external electronic devices.
3.
The 2000-Series has a 2-year warranty and the 5000-Series has a
5-year warranty.
What
are the operating temperature specifications of the 5000 series
chargers?
The
5000 series chargers are designed to operate at 100% of rating
in a 0°/32°F to 50°C/122°F environment.
Is
it possible to simultaneously run your boat engine(s) while having
the Charles battery charger left on?
Yes. The battery
charger has "blocking diodes" on each output and as such
can operate in conjunction with multiple DC power/charging sources.
Our
battery charger will appropriately adjust its output as needed. If
the alternator has a higher voltage than the battery charger's
current charging state, the battery charger's output will remain
low.
Can my battery charger work with two different battery types
simultaneously?
As long as the batteries are of the same cell type, the charger will
not be affected and the batteries will be charged as needed. (Larger batteries, though, will take longer to recover.)
If
the battery cell types are different, the charger is best adjusted
to accommodate the lowest charging rate. For example when trying to
charge Lead Acid and sealed (AGM) batteries, use the “AGM cell
type” setting.
For
9Q-xxxx models only:
How can I adjust my charger to accommodate charging other types
of battery cells?
To adjust the
charger for various types of batteries:
• Turn
the charger off, and then disconnect the output to the batteries
•
Locate the voltage adjustment potentiometer (tinted red)
• Turn
the charger on, then raise or lower the output to the appropriate
voltage.
(For example, 14.2vdc for 12volt chargers, or 28.4vdc for 24volt
chargers.)
*
Check with the battery manufacturer to determine the recommended
voltage setting.
•
Turn the charger off and then reconnect the batteries.
What
is a dripshield?
The dripshield is a charger over-head cover used to inhibit direct
water from above and is recommended where chargers are located in
areas subject to moisture and/or debris from above.
On
the 5000 series SP chargers, where is the switch for choosing the
battery type?
The
switch is located on the back of the charger.
DC Power Products - StartNow
How
can I troubleshoot problems with a StartNow device?
Using
a DC voltmeter, measure from the DC negative stud, to the remote
indicator stud located on the StartNow. When the engine
“cranks”, the voltage on the remote indicator stud will read
approximately 12 volts DC.
Using 2
DC voltmeters, measure the voltage on the Main battery and measure
the voltage on the Reserve battery.
When
the engine “cranks”, you will briefly see the Main battery
voltage "dip/sag" below the Reserve battery voltage, then
they will level off to almost equal in voltage when the StartNow
enables.
Why
does the remote light always seem to be flashing?
Even if the charging source has been removed (such as the alternator
or the battery charger), the remote indicator will remain flashing
the “charge mode” indication until the Main battery becomes
lower than 13 volts DC, or a measurable voltage drop of the Main
battery occurs.
Why
does my indicator come on every time I start my engine, even though
my starting/main battery is fully charged?
The StartNow will generally connect the auxiliary battery during an
engine “crank”, though very little energy will be transferred
from the Auxiliary battery if the main battery has sufficient
charge.
When
using a StartNow/BattCom, which battery should I connect my battery
charger to?
Always connect your battery charger to the Main battery.
The StartNow/BattCom will automatically connect to charge the
Reserve battery, once the Main battery has received an adequate
charge.
AC
Power Products - Isolation
Transformers
Why would a boat need an
Isolation transformer?
To create a safer, “off-grid” electrical AC power source inside
the boat. This eliminates to possibility “stray current” from
nearby boats and eliminates the possibility of AC power leaking into
the water.
Can I use one Isolation
transformer with two shore-power connections?
No, only one shore power source can be connected at a time.
Why does my shore-power
circuit breaker keep “tripping”?
On occasion, there can be a surge of AC amps commonly called
“inrush”. If this becomes a nuisance, a device called a
“transformer Soft Start” will be needed.
What size of Isolation
transformer do I need?
Our isolation transformers are design around the most commonly found
AC power outlet sizes at
If the boat has an electrical
system, then it would be sized to existing shore power connection.
If there is no existing
electrical system, the transformer should be minimally sized to the
largest electrical load.
Why can’t I get power
through the isolation transformer using a 120vac shore power cord?
If your transformer is designed for a 240vac only input, such
as the 93-ISOBOOSTxx-A or the 93-iXFMR12T-A, there is not a
available connection for the shore power “neutral” on the input.
I
already have a transformer, how can I boost low shore power voltage?
If
the transformer is designed for 240 volt AC output, the Charles
93-SMTBST50-A can be adapted to any shoreline transformer up to 50
amperes.
Can
the Isolation transformers alter frequency from 50Hz to 60Hz?
The isolation transformers will not alter the frequency.
Can
the Isolation transformers alter voltage?
Yes, some models can changes the voltage automatically, while others
must be manually changed at the connections to alter voltage.
Why
is the Yellow indicator on my Iso-Boost transformer always on?
The Yellow indicator will be illuminated when the shore power needs
boosted. Many marinas use a 3-phase 208/120 “Wye” power
transformer, making the nominal voltage to the outlet 208vac.
If the Iso-Boost Isolation
Transformer does not appear to be operating:
• Check the input voltage from L1 to L2
only, not from L1 to N or L2 to N. If you check from L1 to N
or L2 to N
you will get a false reading if
there is a poor connection between the shore and the transformer.
•
Make sure sufficient shore power is present. A minimum of 185 volts
AC input is needed to enable the
Iso-Boost.
•
Check the input circuit breakers. If necessary reduce output load
and reset the breaker.
•
Check surface temperature. BEWARE, this device can operate at
a high temperature. If the surface
temperature is approx. 110 degrees Celsius (230 Fahrenheit),
allow time to cool.
•
Try the Manual Override switch located behind the smaller, lower
right access cover.
• If
the Iso-Boost Isolation Transformer appears to be functioning, but
there is no power to the distribution
panel:
•
At the Iso-Boost’s output terminals, make sure there is 100-125
volts AC from L1 to N, and 200-250 volts
AC from L1 to L2.
•
Check the secondary circuit breaker (panel). If necessary, reduce
load and reset the circuit breaker.
If the Iso-Boost
Isolation Transformer appears to be functioning, but there is no
power to the distribution panel:
•
At the Iso-Boost’s output terminals, make sure there is 100-125
volts AC from L1 to N, and 200-250 volts
AC from L1 to L2.
•
Check the secondary circuit breaker (panel). If necessary, reduce
load and reset the circuit breaker.
AC Power Products - A/B
Selector
9x-ABSELxx
AC source
How
can I tell is my A/B selector (9x-ABSELxx-x) is working?
Using an AC voltmeter, check to ensure adequate voltage is coming to
the input terminals of the ABSEL device. Then measure the output
terminals to verify the power is passing through the device.
Onboard
Communications System - C-Phone
Why
am I hearing a lot of static in the handset?
This is a sign of a bad connection. Check all connections to see if
moisture or corrosion has created interference. If this fails to
produce results, try another handset.
If
the above fails, try removing power to the C-Phone system. This
connects all handsets to the incoming line 1 to see if the problem
disappears. This will confirm the wiring to and from the C-Phone
system.
Why
do I hear clicking in my handset?
This is typically a result of a "shorted" connection.
Check
all connections to see if moisture or corrosion has created
interference. If this fails to produce results, try another handset.
If the above fails, try
removing power to the C-Phone system. This connects all handsets to
the incoming line 1 to see if the problem disappears. This will
confirm the wiring to and from the C-Phone system.
Shore
Power Cables - Smart Y
Why
don't I get any power from my Smart Y adapter?
The power phasing could be incorrect. The Smart Y 100 requires two
“in phase” sources of electricity, while the Smart Y 50 requires
two “out of phase” sources of 120-volt electricity.
On the Smart Y 100, if a GREEN indicator is ON and you still receive
no power, check the boats internal breakers.
On
the Smart Y 100, if a RED indicator is ON it is an indication of
improper phasing on the input connections.
If no
indicators are ON check the input connections.
On
the Smart Y 50, if a RED indicator is ON and you still have no
output, check the boats internal circuit breakers.
Why
does the Smart Y 100 have to be used in conjunction with an
isolation transformer?
The Neutral conductor from the shore power outlets is not passed
through the unit.
Why
won't the Smart Y 50 supply 50 amps of current?
The Smart Y 50 is limited to 30 amps due to its 30 amp input
connections.
Why
won't the Smart Y work with only one leg plugged in?
This is an inherent safety feature to keep voltage from
"back-feeding" to an open input plug, preventing possible
shock.
|