Central Office
Terminal (COT) Line Card
- Provides
12:1 Digital Pair-Gain (DPG)
- 2B1Q line coding
- Mounts
in 200 series shelves
- LED
indicators for power, alarms and add/drop synchronization
- Uses
twisted pair infrastructure
- 4TEL,
MLT or GR-909 line testing signatures
- NEBS
level 3 compliant
|
 |
Power Supply
- Input
to power supply is a -48V DC battery
- Powers
up to five COT line cards
- 2
powers supplies required per shelf for 10 DSLs
- DSL
voltages available: ±190V, ±130V or ±100V DC
|
 |
2 Line Add/Drop (A/D) Unit
2 Line Add/Drop (A/DE) End Unit
- Power
and sync LED indicators
- Line
powered
- Can
be used in Distributed or Hybrid configurations
- Supports
up to 200 ohm drop lengths
- Extends
DSL distance up to 24,800 ft. on 19 AWG
- Rugged
design for use at -40° to 65°C (-40° to +149° F)
|
 |
Remote
Terminal (RT) - RT12
- Drops
up to 12 POTS lines
- Supports
up to 200 or 400 ohm drop lengths
- Line
and Express Power configurations
- Can
be used in combination with Point-to-Point or Hybrid configurations
- Sync
LED indicator
- Extends
DSL distance up to 24,800 ft. on 19 AWG
- Rugged design for use at -40° to 65°C (-40° to +149° F)
|
 |
Alarm Card
- One
card per 200 series shelf
- Visual
and audible status alarms
- Self-test
function
|
 |
Pole / Wall / Pedestal Mount Repeater
& Isolation Repeater
- Extends
DSL distance up to 24,800 ft. on 19 AWG
- Line
powered
- LED
for sync indication
- Rugged
design for use at -40° to 65°C (-40 to +149°F)
- Weather-tight
housing
- Isolation
Repeater required for Back Power configurations
|
| |
Express Power Card
- Extends
DSL distance
- Application
requires one Express Power Card per COT Line Card
- Rugged
design for use at -40° to 65°C (-40° to +149° F)
|
 |
Remote
Terminal Cabinet (RTC) - RTC12 & RTC24
- Line
powered
- Drops
up to 24 POTS lines
- Supports
200 or 400 ohm drop lengths
- Meets
the environmental stressing sections of GR-487-CORE
- Houses
up to two Mid-Span / Remote Terminal Power Supplies (±130V) per
cabinet
- Extends
DSL distance up to 24,800 ft. on 19 AWG
- 3
options for extended reach applications:
- Express Power
- Local Power (requires BBU for lifeline service)
- Back Power (requires BBU for lifeline service)
- Rugged
design for use at -40° to 65°C (-40° to +149° F)
- Cable
stubs available upon request
|
| |
Remote Terminal Power Supply
- Local
and Back Power configurations require one power supply per
DSL
- Input
power from BBU or 115V AC
- Provides
GR-1089 A2 protection
- Double-wide
CS-239 size mechanics
|
| |
Battery Backup Unit (BBU)
- 28
amp-hours @ 3.5 amps continuous backup service
- Meets
the environmental stressing sections of GR-487-CORE
- LED
indicators for proper operation, low battery and fault conditions
- Major
and minor alarm reporting capabilities
- Analog
meters for DC voltage and DC amperage status
- Rugged
design for use at -40° to 65°C (-40° to +149° F)
|
 |
200 Series Shelf and Baffle
- 23”
DML 201 shelf; maximum 120 lines (13 slots, 10 COT line cards); uses
7” of vertical rack space (four rack units)
- 19”
DML 205 shelf; maximum 84 lines (10 slots, 7 COT line cards); uses
7” of vertical rack space (four rack units)
- Baffles
for 19” and 23” shelves; uses 1.75” of vertical rack space (one
rack unit)
|
| |
200 Series Fan Tray
- Fan
trays for 19” and 23” shelves; uses 1.75” of vertical rack space
(one rack unit)
- Fan
trays feature 172 CFM output and quiet operation
|