5000
SP Series Marine Electronic Battery Chargers
12 Volt - 10, 15, 20,
30, 40, 50, 60, 80 & 100 AMP
24 Volt - 10, 15, 20, 30, 40, 50 & 60 AMP

5000 SP Series Marine Electronic Battery Chargers are the best choice for
high-performance Marine UL listed products.
Utilizing high-quality components and corrosion-resistant,
anodized aluminum housing, the units are built to last, performing in the
toughest of marine environments. Charles 5000 SP battery chargers feature a
battery type selector switch. This feature allows the boater to charge either
lead acid, gel, or AGM batteries.
Marine UL listing ensures durability and safety
- Only complete line of battery chargers approved by Marine
UL's stringent specifications, testing and evaluation
- Tested for durability against static, impact, vibration and
shock
- DC ammeter indicates the charge rate
- Ignition protected (USCG-33 CFR 183.410)
- AC and DC fuse protection
Multi-step charging with temperature compensation
- Restores up to 3 individual battery banks simultaneously
- Internal temperature compensation
(12V 30-100 amp models and 24V 20-60 amp models) automatically adjusts
output to precisely charge batteries according to ambient conditions
Corrosion resistant housing and components
- Constructed of tough, anodized aluminum housing that stands
up to the elements-including extreme heat, humidity and salt air
- Circuit boards with UL recommended coatings provide the
ultimate in environmental protection and hydrolyte stability-meets requirements of
MIL-1-46058C
Run cool and quiet
- Cooling fan only operates during peak current demands
- Virtually no RFI or EMI interference exceeds FCC/Class B
requirements
Easy to install and service
- Battery selector switch allows charger
to be used with lead acid, gel, or AGM batteries
- Exterior slots for easy mounting
- Easy access to terminal connections and fuses
- 5 Year warranty, made in the USA
| Specifications |
|
12 Volt Models |
| Charles
Part Number |
Amperage |
AC
Input Voltage Range |
DC
Output Voltage Range |
Frequency |
Dimensions |
| 120
VAC, 50/60 Hz |
| 93-12105SP-A |
10 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 8" |
| 93-12155SP-A |
15 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 8" |
| 93-12205SP-A |
20 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 8" |
| 93-12305SP-A |
30 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 10.5" |
| 93-12405SP-A |
40 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 13.25" |
| 93-12505SP-A |
50 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 93-12605SP-A |
60 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 93-12805SP-A |
80 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 93-121005SP-A |
100 |
95-140
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 21-104589-0 |
Dripshield
for 10 to 40 amp 5000 SP Series Models |
| 93-TEMPPROBE-A |
Temperature
probe for 30, 80 and 100 amp 5000 SP Series 12V Models |
| 220
VAC, 50/60 Hz |
| 9C-12205SPI-A |
20 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 8" |
| 9C-12305SPI-A |
30 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 10.5" |
| 9C-12405SPI-A |
40 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 13.25" |
| 9C-12505SPI-A |
50 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 9C-12605SPI-A |
60 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 9C-12805SPI-A |
80 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 9C-121005SPI-A |
100 |
200-240
VAC |
12V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
|
21-104589-0
|
Dripshield
for 10 to 40 amp 5000 SP Series Models |
| 93-TEMPPROBE-A |
Temperature
probe for 30, 80 and 100 amp 5000 SP Series 12V Models |
|
|
24 Volt Models |
| Charles
Part Number |
Amperage |
AC
Input Voltage Range |
DC
Output Voltage Range |
Frequency |
Dimensions |
| 120
VAC, 50/60 Hz |
| 93-24105SP-A |
10 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 10.5" |
| 93-24205SP-A |
20 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 13.25" |
| 93-24305SP-A |
30 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 93-24405SP-A |
40 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 93-24505SP-A |
50 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 93-24605SP-A |
60 |
95-140
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 21-104589-0 |
Dripshield
for 10 to 40 amp 5000 SP Series Models |
| 93-TEMPPROBE-A |
Temperature
probe for 50 and 60 amp 5000 SP Series 24V Models |
| 220
VAC, 50/60 Hz |
| 9C-24155SPI-A |
15 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 13.25" |
| 9C-24205SPI-A |
20 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 13.25" |
| 9C-24305SPI-A |
30 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 9C-24405SPI-A |
40 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 15.25" |
| 9C-24505SPI-A |
50 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
| 9C-24605SPI-A |
60 |
200-240
VAC |
24V |
50Hz
or 60Hz |
3.7"
x 9.5" x 21.5" |
|
21-104589-0
|
Dripshield
for 10 to 40 amp 5000 SP Series Models |
| 93-TEMPPROBE-A |
Temperature
probe for 50 and 60 amp 5000 SP Series 24V Models |
|
|
|
|